CurbScoop
CurbScoopBuildingsLenox Hill52 EAST 78 STREET

52 EAST 78 STREET

Manhattan· Lenox Hill· built 1916class D4BBL 1013920046
Open listing source

52 EAST 78 STREET is a 47-unit building in Lenox Hill, Manhattan, built in 1916.

1 unit is on the market here right now.

City records show 30 DOB permits and 72 open violations on file.

Units (res)
47
Floors
13.0
Lot ft²
4,061 ft²
Bldg ft²
28,080 ft²
Assessed
$3.86M
DOF total
Comps L5y
0

Active sale listings (1)

AddressNeighborhoodPrice$/ft²SqftBeds/Bathsvs compDOMRiskScore
52 EAST 78 STREET #4CD
Manhattan · built 1916
Lenox Hill$949K-0 ft²2 bd · 2 ba-602
4 HPD-C6 DOBbedbug
15.1Source

Transaction history (0)

Every recorded deed for this tax lot.

No recorded transactions for this BBL yet.

Building risk + activity

HPD violations (last 40)
  • I
    §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
    Nov 15, 2023 · VIOLATION DISMISSED
  • I
    §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
    Oct 25, 2019 · VIOLATION DISMISSED
  • B
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
    Oct 17, 2016 · #5C · INVALID CERTIFICATION
  • B
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
    Oct 17, 2016 · #6C · INVALID CERTIFICATION
  • B
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
    Oct 17, 2016 · #5C · INVALID CERTIFICATION
  • B
    § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
    Oct 17, 2016 · #6C · INVALID CERTIFICATION
  • A
    § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING ON WALL AT PUBLIC HALL, 1st STORY
    Sep 30, 2016 · VIOLATION DISMISSED
  • A
    § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY
    Sep 30, 2016 · VIOLATION DISMISSED
  • A
    § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING ON WALL AT PUBLIC HALL, 1st STORY
    Sep 30, 2016 · VIOLATION DISMISSED
  • A
    § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
    Sep 30, 2016 · VIOLATION DISMISSED
  • C
    § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING ON WALL AT PUBLIC HALL, 1st STORY
    Sep 30, 2016 · VIOLATION DISMISSED
  • B
    § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK CEILING PIPE 10 STY PUBLIC HALL EAST STAIR WELL.
    Mar 4, 1998 · INVALID CERTIFICATION
  • B
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 9 STY NORTHWEST APT 9E EAST HOLMAN. LOCATED AT APT 9E
    Mar 4, 1998 · #9E · INVALID CERTIFICATION
  • B
    § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MOISTURE PENETRATING CEILING UPPER ROOM AT NORTH 9 STY NORTH APT 9E. , SECTION '' ''
    Feb 27, 1998 · #9E · INVALID CERTIFICATION
  • B
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING & NORTH WALL UPPER & LOWER ROOM AT NORTH 9 STY NORTH APT 9E. , SECTION '' ''
    Feb 27, 1998 · #9E · INVALID CERTIFICATION
  • B
    § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MOISTURE PENETRATING EAST WALL CENTER SECTION PRIVATE HALL AT NORTH 9 STY NORTH APT 9E. , SECTION '' ''
    Feb 27, 1998 · #9E · INVALID CERTIFICATION
  • B
    § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER UPPER ROOM 9 STY NORTHWEST DUPLEX APT 9E , SECTION '' ''
    Apr 5, 1996 · #9E · INVALID CERTIFICATION
  • B
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL PRIVATE HALL FROM 9 STY NORTHWEST DUPLEX APT 9E TO APT 8D , SECTION '' ''
    Apr 5, 1996 · #9E · INVALID CERTIFICATION
  • B
    § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EAST WALL PRIVATE HALL FROM 9 STY NORTHWEST DUPLEX APT 9E TO APT 8D , SECTION '' ''
    Apr 5, 1996 · #9E · INVALID CERTIFICATION
  • B
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING UPPER ROOM 9 STY NORTHWEST DUPLEX APT 9E , SECTION '' ''
    Apr 5, 1996 · #9E · INVALID CERTIFICATION
  • A
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING CENTER NORTH SECTION 9 STY WEST APT 9E UPPER LEVEL ROOM , SECTION '' ''
    Feb 2, 1996 · #9E · NOV SENT OUT
  • B
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 10 STY NORTHEAST APT 10C NORTHWEST ROOM , SECTION '' ''
    Jan 12, 1996 · #10C · INVALID CERTIFICATION
  • B
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PARQUET FLOOR 10 STY NORTHEAST APT 10C NORTHEAST & NORTHWEST ROOMS , SECTION '' ''
    Jan 12, 1996 · #10C · INVALID CERTIFICATION
  • A
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE TOP SASH WINDOW AT WEST FOR HIGHT CEILING AREA AT 9 STY REAR NORTHWEST APT 9E. , SECTION '' ''
    Oct 19, 1992 · #9E · NOV SENT OUT
  • A
    § 27-2005 ADM CODE REFIT UPPER SASH & EAST WINDOW CENTER ROOM 9 STY NORTH APT 9E. , SECTION '' ''
    Jan 15, 1992 · #9E · NOV SENT OUT
  • B
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 9 STY NORTH APT 9E HOLMAN. , SECTION '' ''
    Jan 15, 1992 · #9E · INVALID CERTIFICATION
  • B
    § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING NIGHT INSPECTION LIGHT FIXTURE PRESENT NOT ON 200 WATTS.
    Sep 17, 1991 · INVALID CERTIFICATION
  • B
    § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 9 STY NORTH DUPLEX APT 9D STRUPP. , SECTION '' ''
    Sep 11, 1991 · #9D · INVALID CERTIFICATION
  • C
    SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED FRONT DOOR TO 1 STY PUBLIC HALL.
    Sep 11, 1991 · VIOLATION DISMISSED
  • B
    D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 2 STY APARTMENT 2B.
    Sep 11, 1991 · INVALID CERTIFICATION
  • A
    § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT BATHROOM WINDOW SILL 7 STY SOUTHWEST APT 7C. LOCATED AT APT 7C
    Sep 11, 1991 · #7C · NOV SENT OUT
  • B
    § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PARQUET FLOOR 7 STY SOUTHWEST APT 7C PRIVATE HALL & SOUTH ROOM. LOCATED AT APT 7C
    Sep 11, 1991 · #7C · INVALID CERTIFICATION
  • B
    § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS REAR ROOM 9 STY REAR APT 9D REAR BUILDING 61 EAST 77 ST. , SECTION '' ''
    Sep 11, 1991 · #9D · INVALID CERTIFICATION
  • B
    D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALL AND CEILING NORTH FIRE STAIRS 1ST STY TO CELLAR.
    Sep 6, 1991 · INVALID CERTIFICATION
  • A
    § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ROTTED INTERIOR WINDOW FRAME SOUTHEAST WINDOW 8 STY SOUTH APT 8D. , SECTION '' ''
    Sep 6, 1991 · #8D · NOV SENT OUT
  • A
    § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WATER COOLING MACHINERY SOUTH SECTION ROOF AT CENTER BLDG 61 E 77 ST.
    Sep 6, 1991 · NOV SENT OUT
  • B
    D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING 12TH STY NORTH FIRE STAIRS.
    Sep 6, 1991 · INVALID CERTIFICATION
  • C
    D26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1ST STY PUBLIC HALL NEAR MAILBOXES AND AT DOOR TO BOILER ROOM.
    Sep 6, 1991 · VIOLATION DISMISSED
  • C
    D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK ENTRANCE DOOR STREET TO 1AT STY PUBLIC HALL.
    Sep 6, 1991 · VIOLATION DISMISSED
  • A
    D26-22.03 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER.
    Sep 6, 1991 · VIOLATION DISMISSED
DOB permits (last 30)
  • OTJul 2, 2001
    LENOX HILL RADIOLOGY MED.IMAGING
  • OTOct 30, 1997
    GIOVANNITTI ,INC.
  • OT-
    L & N CONSTRUCTION CORP.
  • OT-
    YORK RESTORATION CORP
  • OT-
    MANTIS AND ASSOCIATES LLC
  • OT-
    ELEMENT INTERIORS INC
  • OT-
    NOVA REMODELING INC
  • PL-
    BMC PLBG CORP
  • OT-
    HIGHLINE STUDIO CUSTOM
  • PL-
    P.S.I. MECHANICAL
  • OT-
    LCS RESTORATION CORP
  • OT-
    LCS RESTORATION CORP
  • PL-
    COOPER MECHANICAL INC
  • BL-
    BMC PLBG CORP
  • FB-
    BMC PLBG CORP
  • MH-
    ELEMENT INTERIORS INC
  • OT-
    AMIS INC.
  • OT-
    GALICIA CONTRACTING & RESTORATIO
  • PL-
    ROM PIPING & HTG INC
  • EQ-
    OUTDOOR INSTALLATIONS LLC
  • OT-
    STRUCTURE TECHNOLOGY
  • MH-
    STRUCTURE TECHNOLOGY
  • OT-
    KUSHNER STUDIOS
  • OT-
    L & N CONSTRUCTION CORP.
  • PL-
    GEORGE BRESLAW & SONS INC
  • PL-
    CODE MECHANICAL INC
  • OT-
    LENOX HILL RADIOLOGY &MED.IMAGIN
  • OT-
    LENOX HILL RADIOLOGY MED.IMAGING
  • EQ-
    PHOENIX SUTTON STR INC
  • EQ-
    ROCKLEDGE SCAFFOLD
DOB violations
  • Aug 6, 2019E-ELEVATOR ELEVATORREQUIRED
  • Jan 3, 2019FISP-FACADE SAFETY PROGRAM FACADE REQUIRED
  • Nov 14, 2016ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED
  • May 15, 2014LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
  • May 15, 2014LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
  • Jan 2, 2013AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
  • Jan 2, 2013AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
  • Jan 2, 2013AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
  • Jan 2, 2013AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
  • Mar 2, 2010E-ELEVATOR ELEVATORREQUIRED
  • Oct 14, 2009E-ELEVATOR ELEVATORREQUIRED
  • Sep 3, 2008E-ELEVATOR ELEVATORREQUIRED
  • Aug 15, 2007E-ELEVATOR ELEVATORREQUIRED
  • Jan 19, 2007LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • Jan 6, 2006LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • Feb 13, 2004LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • Mar 19, 2003LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • Jun 28, 2002E-ELEVATOR ELEVATORREQUIRED
  • Mar 26, 2002LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • Jun 22, 2001E-ELEVATOR ELEVATORREQUIRED
  • Feb 27, 2001LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • Feb 27, 2001LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • May 9, 2000E-ELEVATOR ELEVATORREQUIRED
  • Feb 7, 2000LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • May 4, 1998LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • May 4, 1998LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • Aug 29, 1995LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • Sep 21, 1994E-ELEVATOR ELEVATORREQUIRED
  • Mar 18, 1994LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • Mar 18, 1993LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
  • Apr 4, 1989E-ELEVATOR ELEVATORREQUIRED
  • Oct 26, 1988E-ELEVATOR ELEVATORREQUIRED

More buildings in Lenox Hill

Sources & freshness

Research contract nyc_property_research.v1 · snapshot Sep 23, 2026

Stable property ID: nyc:bbl:1013920046

This identifier represents an NYC tax lot. Condo and co-op apartment identity must be resolved separately.

Tax lot and building facts

NYC Department of City Planning (PLUTO)

completed
1 tax-lot record in the current corpus · latest record Sep 20, 2026

Pipeline completed Sep 20, 2026

The current PLUTO pipeline is configured for Manhattan and Brooklyn.

PLUTO describes the tax lot and buildings, not legal ownership of an individual apartment.

Marketed sale listings

StreetEasy, observed by CurbScoop

completed
1 active sale listing in the current corpus · latest record Dec 6, 2024

Pipeline completed Aug 31, 2026

The current sales-listing pipeline is configured for Manhattan and Brooklyn.

Listing observations describe marketed state and are not proof of a closing or exhaustive market coverage.

Recorded transfers

NYC Department of Finance, Office of the City Register (ACRIS)

completed
0 recorded deeds in the current corpus

Pipeline completed Sep 23, 2026

Deed document types associated with this BBL in the current CurbScoop corpus.

Recording can lag a transaction, and a deed with no stated consideration is not evidence of a market sale.

DOB permits

NYC Department of Buildings via NYC Open Data

completed
76 permits in the current corpus · latest record Jul 2, 2001

Pipeline completed Sep 23, 2026

The current DOB permit pipeline is configured for Manhattan and Brooklyn.

A filing or permit does not prove that work was completed or that all work at the property was filed.

HPD violations

NYC Department of Housing Preservation and Development via NYC Open Data

completed
43 violations in the current corpus · latest record Feb 24, 2025

Pipeline completed Sep 23, 2026

The current HPD violation pipeline is configured for Manhattan and Brooklyn.

Status and correction timing come from the published agency record and may change after CurbScoop observes it.

DOB violations

NYC Department of Buildings via NYC Open Data

completed
32 violations in the current corpus · latest record Dec 16, 2022

Pipeline completed Sep 23, 2026

The current DOB violation pipeline is configured for Manhattan and Brooklyn.

Absence from the current corpus is not proof that a building has no regulatory issue.

Counts and dates describe the current CurbScoop corpus. They are not a guarantee of exhaustive agency or listing coverage.

Reading these records

The transaction history above comes from ACRIS, the city's register of recorded deeds - it shows what actually closed, not what was asked. To compare that against what similar units are listed at, see how to find comps and asking price vs sale price. The BBL identifying this lot is explained in what is a BBL. Wider context for the area is on the Lenox Hill market page.